G0B – Station safety: electrical shock, grounding, fusing, interlocks, and wiring; antenna and tower safety - [[G0B01]] (A) Which wire or wires in a four-conductor 240 VAC circuit should be attached to fuses or circuit breakers? - A. Only the hot wires - B. Only the neutral wire - C. Only the ground wire - D. All wires -- - [[G0B02]] (C) According to the National Electrical Code, what is the minimum wire size that may be used safely for wiring with a 20-ampere circuit breaker? - A. AWG number 20 - B. AWG number 16 - C. AWG number 12 - D. AWG number 8 -- - [[G0B03]] (D) Which size of fuse or circuit breaker would be appropriate to use with a circuit that uses AWG number 14 wiring? - A. 30 amperes - B. 25 amperes - C. 20 amperes - D. 15 amperes -- - [[G0B04]] (B) Where should the station’s lightning protection ground system be located? - A. As close to the station equipment as possible - B. Outside the building - C. Next to the closest power pole - D. Parallel to the water supply line -- - [[G0B05]] (B) Which of the following conditions will cause a ground fault circuit interrupter (GFCI) to disconnect AC power? - A. Current flowing from one or more of the hot wires to the neutral wire - B. Current flowing from one or more of the hot wires directly to ground - C. Overvoltage on the hot wires - D. All these choices are correct -- - [[G0B06]] (C) Which of the following is covered by the National Electrical Code? - A. Acceptable bandwidth limits - B. Acceptable modulation limits - C. Electrical safety of the station - D. RF exposure limits of the human body -- - [[G0B07]] (B) Which of these choices should be observed when climbing a tower using a safety harness? - A. Always hold on to the tower with one hand - B. Confirm that the harness is rated for the weight of the climber and that it is within its allowable service life - C. Ensure that all heavy tools are securely fastened to the harness - D. All these choices are correct -- - [[G0B08]] (B) What should be done before climbing a tower that supports electrically powered devices? - A. Notify the electric company that a person will be working on the tower - B. Make sure all circuits that supply power to the tower are locked out and tagged - C. Unground the base of the tower - D. All these choices are correct -- - [[G0B09]] (A) Which of the following is true of an emergency generator installation? - A. The generator should be operated in a well-ventilated area - B. The generator must be insulated from ground - C. Fuel should be stored near the generator for rapid refueling in case of an emergency - D. All these choices are correct -- - [[G0B10]] (A) Which of the following is a danger from lead-tin solder? - A. Lead can contaminate food if hands are not washed carefully after handling the solder - B. High voltages can cause lead-tin solder to disintegrate suddenly - C. Tin in the solder can “cold flow,” causing shorts in the circuit - D. RF energy can convert the lead into a poisonous gas -- - [[G0B11]] (D) Which of the following is required for lightning protection ground rods? - A. They must be bonded to all buried water and gas lines - B. Bends in ground wires must be made as close as possible to a right angle - C. Lightning grounds must be connected to all ungrounded wiring - D. They must be bonded together with all other grounds -- - [[G0B12]] (C) What is the purpose of a power supply interlock? - A. To prevent unauthorized changes to the circuit that would void the manufacturer’s warranty - B. To shut down the unit if it becomes too hot - C. To ensure that dangerous voltages are removed if the cabinet is opened - D. To shut off the power supply if too much voltage is produced -- - [[G0B13]] (A) Where should lightning arrestors be located? - A. Where the feed lines enter the building - B. On the antenna, opposite the feed point - C. In series with each ground lead - D. At the closest power pole ground electrode